1
برق و الکترونیک::
پیام رویداد اتصال گرم ماژول
3-8 Module Hot Swap event message 3-24
When the Module Handle in the Module is closed, the MMC sends a Module Hot Swap (Module Handle Closed) event message to the Carrier IPMC, as described in Table 3-8, "Module Hot Swap event message."
When the Module Handle in the Module is opened, the MMC in the Module sends a Module Hot Swap (Handle Opened) event message to the Carrier IPMC (as described in Section 3-8, "Module Hot Swap event message." )
Table 3-8 Module Hot Swap event message
REQ 3.54 When Management Power (MP) is applied to the MMC and its associated management circuitry, the ENABLE# signal is active, and a valid Geographic Address has been read, the MMC shall read the state of the Module Handle and send a Module Hot Swap (Module Handle Opened or Module Handle Closed) event message appropriately, as described in Table 3-8, "Module Hot Swap event message."